IM DA100-11E
7-4
7.4 Setting Data Output Format (Operation mode)
The operation mode parameters are output in the following order by the TS1 + “Device Trigger
(GET)” + LF command:
SR
Measured range setting data for the first channel
SR Measured range setting data for the last channel
SN
Unit setting data for the first channel
Unit setting data for the last channel
SN
SA
SA
SV
SV
EN
Alarm setting data for the first channel
Alarm setting data for the last channel
Moving average setting data for the last channel
Moving average setting data for the first channel
Output completed.
CrLf
CrLf
CrLf
CrLf
CrLf
CrLf
CrLf
CrLf
CrLf
SO
Computation expression setting data for the first computation channel
SO Computation expression setting data for the last computation channel
CrLf
CrLf
SI
Setting data for No. 1 timer
SI Setting data for No. 6 timer
CrLf
CrLf
SQ
Setting data for No. 1 match time
SQ Setting data for No. 3 match time
CrLf
CrLf
SL
Setting data for No. 1 event action
SL Setting data for No. 30 event action
CrLf
CrLf
SX
Setting data for No. 1 group
SX Setting data for No. 7 group
CrLf
CrLf
SK
Constant setting data for the first constant number
SK Constant setting data for the last constant number
CrLf
CrLf
Setting data for the channels in the range specified by the LF command are output for every subunit.
Channel numbers are output in the order of input channels and computation channels. For example,
when LF005 , A10 is set, the data are output starting from the input channel 005 to the last input
channel. Then, the data are output starting from computation channels A01 to A10.
Data are output in the order of setting parameters subsequent to the setting command. Each data
item is delimited with a comma (,).
Alarm setting data
For alarm setting data, setting data from level 1 to level 4 are output for every channel.
SA
Level 1 alarm setting data
CrLf
CrLf
CrLf
CrLf
CrLf
CrLf
CrLf
Level 4 alarm setting data
Level 3 alarm setting data
Level 2 alarm setting data
CrLf
Level 1 alarm setting data
CrLf
CrLf
CrLf
Level 4 alarm setting data
Level 3 alarm setting data
Level 2 alarm setting data
CrLf
SA
SA
First channel
Second channel
Last channel
Level 1 alarm setting data
Level 4 alarm setting data
Level 3 alarm setting data
Level 2 alarm setting data
SA
SA
SA