IM DA100-11E
7-1
Output Format
7
7.1 Functions as Talker
There are the following thirteen types of data output:
Measured data output (ASCII code): TS0 + “Device Trigger (GET)” + FM0
Measured data output (binary code): TS0 + “Device Trigger (GET)” + FM1
Computed data output (ASCII code): TS0 + “Device Trigger (GET)” + FM2
Computed data output (binary code): TS0 + “Device Trigger (GET)” + FM3
Setting of data output in the operation mode: TS1 + “Device Trigger (GET)” + LF
Unit and decimal point position data output: TS2 + “Device Trigger (GET)” + LF
System configuration data output: TS5 + “Device Trigger (GET)” + CF
A/D calibration data output: TS8 + “Device Trigger (GET)” + LF
Setting of data output in the setup mode: TS9 + “Device Trigger (GET)” + LF
Output the hourly report using the report function: TS4+"GET"+RF0
Output the daily report using the report function: TS3+"GET"+RF1
Output the monthly report using the report function: TS3+"GET"+RF2
Output the status of the hourly/daily/monthly report: TS3+"GET"+RF3
Measured/computed or report data output (TS0/TS3)
After executing the device trigger“GET ” be sure to output data using the FM command. Execution
of “GET” alone without executing the FM command does not output the data. After reading all the
data specified by the FM command, subsequent specification of the FM command without executing
“GET” enables the data within a scan to be output.
Setting data output (TS1, TS2, TS8 or TS9)
After transmitting the device trigger“GET ” be sure to output data using the LF command. Execution
of “GET” alone without executing the LF command does not output the data. After reading all the
data specified by the LF command, subsequent specification of another channel using the LF command
enables the data contents to be output. A/D calibration data output by the TS8 command can be
executed in the A/D calibration mode only.
Report output (TS4)
After transmitting the device trigger “GET ” be sure to read the data using the RF command. Execution
of “GET“ alone without executing the RF command does not read the data. After reading all the
specified data with the RF command, subsequent specification of another channel using the RF
command without executing “GET“ enables that data to be read.
System configuration output (TS5)
After transmitting the device trigger“GET,” be sure to output data using the CF command. Execution
of “GET” alone without executing the CF command does not output data.
Note
Do not transmit the FM, LF, CF, or RF command before outputting data for specified channels.
If an FM, LF, CF, or RF command is received while data are being transmitted, transmission of the data is suspended
automatically.
If the type of output data is changed using the TS command after the execution of “GET,” the changed contents are not
reflected without executing “GET” again. Execute “GET” again.
After executing “GET,” the execution of “GET” again without outputting data using the FM, LF, CF, or RF command or
without completing the data output sets new data to the buffer. Be careful because old data are lost.