In the ―This Controller‖ area, select the ―Channel‖ (1(Integral)), select the ―Communication Command‖ (500CPU Write),
the starting data table address for the data to be sent (I:1.0), and the Size in Elements (number of data words) (4). In the
―Target Device‖ area, enter the starting data table address of the MW100 (N30:0 for Communication Channel C01), and
the ―Routing Information File (RI) (RI11:0). Then click on the ―MultiHop tab at the top of the Setup Screen.
In the ―To Address‖ area, enter the IP address of the MW100 (192.168.1.101). Then click on the close window (X) at the
top right of the Setup Screen (the screen can also be closed by clicking on the ―Setup Screen‖ In the MSG instruction. The
MSG Write to the MW100 is now complete.