Yokogawa Data Acquisition with PID Control CX2000 Manuel d'utilisateur

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Capteurs Yokogawa Data Acquisition with PID Control CX2000. Yokogawa Data Acquisition with PID Control CX2000 User Manual [en] Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 55
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
Users
Manual
DXA120
DAQSTANDARD
DX-P Hardware Congurator
IM 04L41B01-65EN
4th Edition
Vue de la page 0
1 2 3 4 5 6 ... 54 55

Résumé du contenu

Page 1 - DX-P Hardware Congurator

User’sManualDXA120DAQSTANDARDDX-P Hardware ConguratorIM 04L41B01-65EN4th Edition

Page 2 - User Registration

1-2IM 04L41B01-65EN Connection (Login) Conditions DXP(Style S4 or later)AdministratorSetup data12345678910262728293021222324251617181920111213141

Page 3 - Revisions

1-3IM 04L41B01-65EN1234IndexBefore Using the DAQSTANDARDViewing the Contents of the Login Information and Batch System SettingsOnly the administrator

Page 4

1-4IM 04L41B01-65EN1.2 Required PC System EnvironmentHardwarePersonal ComputerAcomputerwhichrunsonWindowsXP,WindowsVista,Windows7,orWind

Page 5

2-1IM04L41B01-65EN1234IndexViewing and Creating Setup Data2.1 Confirming the Setup DataStarting the DX-P Hardware ConfiguratorFrom the Start menu, se

Page 6 - How to Use This Manual

2-2IM04L41B01-65ENConfirming the Setup Data Click this tab to open “Meas”Click this tab to open “Math”Click this tab to open “Settings”Click this tab

Page 7 - Contents

2-3IM04L41B01-65EN1234IndexViewing and Creating Setup DataConfirming the Login Information and the Batch System SettingsTo confirm the information oth

Page 8 - Chapter 4 Troubleshooting

2-4IM04L41B01-65ENConfirming Batch System Settings2. Click here (also selectable from [Setting] - [System Mode Setting])1. Select this tab.Login funct

Page 9 - Creating Setup Data

2-5IM04L41B01-65EN1234IndexViewing and Creating Setup Data2.2 ConfigurationThis operation is for creating new setup data (excluding the login informa

Page 10 - How Data Is Managed

2-6IM04L41B01-65EN2.3 Setting the Measurement ChannelsSelect this tabDouble-click to set the channelDifference computationScalingSquare rootSelect th

Page 11 - User Locked

2-7IM04L41B01-65EN1234IndexViewing and Creating Setup DataInput Type and SpanMode, Range/TypeSelect from the list of choices from the pull-down menu.I

Page 12 - Operating System (OS)

PRS 108-01EUser RegistrationThank you for purchasing YOKOGAWA products.We invite you to register your products in order to receive the most up to date

Page 13 - IM04L41B01-65EN

2-8IM04L41B01-65ENScale L, Scale U, and Decimal PointEnter the upper and lower limit values to which you wish to convert the input values. Set the dec

Page 14 - Confirming the Setup Data

2-9IM04L41B01-65EN1234IndexViewing and Creating Setup DataGraphDivisionsSelect the number of scale divisions.Bar GraphSelectthereferencepositionof

Page 15 - Login Mode

2-10IM04L41B01-65ENCopying and Pasting Setup DataTheitemscheckedin[CopyDetails]canbecopiedandpasted.Clickthechannelnumbertoselectthe

Page 16

2-11IM04L41B01-65EN1234IndexViewing and Creating Setup Data2.4 Setting the Computation Channels (/M1 Option)Double-click when setting each channel.Se

Page 17 - 2.2 Configuration

2-12IM04L41B01-65ENDisplay SpanSets the upper and lower limits of the display.The range is from –9999999 to 99999999. Set the number of digits to the

Page 18

2-13IM04L41B01-65EN1234IndexViewing and Creating Setup DataSetting One Computation Channel at a TimeThe items in the [Math] tab can be configured for

Page 19 - Input Type and Span

2-14IM04L41B01-65EN2.5 Configuring the Engineering ModeScreen DisplaySelect this tab.Recovers by a key operation.Recovers by a key operation or alarm

Page 20 - Display Zone

2-15IM04L41B01-65EN1234IndexViewing and Creating Setup DataMessage/FileEnter the group name.Select the group.Enter the message.Click here (also select

Page 21 - Display Color

2-16IM04L41B01-65EN Group/Trip LineSelect the tab of the group to be configured.Check the channels that you wish to register to the selected group (bl

Page 22 - Setting One Channel at a Time

2-17IM04L41B01-65EN1234IndexViewing and Creating Setup DataClick here (also selectable from [Setting] - [Engineering Mode Setting])Enter the view grou

Page 23 - Constant

iIM 04L41B01-65ENThank you for purchasing the DAQSTANDARD (model name: DXA120).This manual explains how to use the software. Please read this manual c

Page 24 - Times (Number of Samples)

2-18IM04L41B01-65ENBatch Click here (also selectable from [Setting] - [Engineering Mode Setting]).Automatically increase the lot number by 1 at Memor

Page 25

2-19IM04L41B01-65EN1234IndexViewing and Creating Setup Data2.6 Configuring the System ModeAlarm/Relay/Remote2. Click here (also selectable from [Sett

Page 26 - Screen Display

2-20IM04L41B01-65ENRemote (Option, /R1)You can assign items to be controlled by the eight remote control terminals. This is possible, if the remote fu

Page 27 - Message/File

2-21IM04L41B01-65EN1234IndexViewing and Creating Setup DataMemory TimeupSpecify the date and time to save the data in the internal memory to the exter

Page 28 - Group/Trip Line

2-22IM04L41B01-65ENApplication Click here (also selectable from [Setting] - [System Mode Setting]).Check here if you wish to clear the waveform displ

Page 29 - USER Key and Daylight Saving

2-23IM04L41B01-65EN1234IndexViewing and Creating Setup DataResetReset the results of TLOG computation when the timer expires.Save DataMeasured/compute

Page 30 - Calibration Correction

2-24IM04L41B01-65ENTemperature Unit, Time Zone, Time deviation limit, System Relay and Auxiliary Functions Click here (also selectable from [Setting]

Page 31 - Alarm/Relay/Remote

2-25IM04L41B01-65EN1234IndexViewing and Creating Setup Data• Displayed Language Select the language to be used on the display.• Partial Expanded Di

Page 32

2-26IM04L41B01-65ENNetworkThe“MemoryDataOut”settingisvoidontheDX100P/DX200P.Setting the TCP/IP1. Click here (also selectable from [Setting] -

Page 33

2-27IM04L41B01-65EN1234IndexViewing and Creating Setup DataFTP ConnectionSpecify the primary and secondary file transfer destinations (FTP servers). 2

Page 34 - Timer (/M1 Option)

iiIM 04L41B01-65ENTerms and Conditions of the Software LicenseNOTICE - PLEASE READ CAREFULLY BEFORE USEThankyouverymuchforpurchasingthismedium

Page 35

2-28IM04L41B01-65ENSetting the Serial Communication • Data Length Select the data length from the following list. Make sure to select 8 bits when o

Page 36 - Functions

2-29IM04L41B01-65EN1234IndexViewing and Creating Setup DataSetting the Modbus MasterSet the command.Data typeSelect whether or not use command.Registe

Page 37 - Active Storage Change

2-30IM04L41B01-65ENSetting the Web ServerMonitor pageSelect whether or not use the Web server.Operator pageSelect whether or not use Monitor/Operator

Page 38

2-31IM04L41B01-65EN1234IndexViewing and Creating Setup DataSetting the E-Mail TransmissionTransmit e-mail when creating a report.Transmit e-mail when

Page 39 - Select the

2-32IM04L41B01-65ENSetting SNTPSNTP clientfunctionSNTP serverfunction• Basic • SNTP server Select [ON] when using the SNTP server function. The DX

Page 40 - • RS-422A/485 Protocol

2-33IM04L41B01-65EN1234IndexViewing and Creating Setup Data2.7 Adjusting the Setup Data (Checking the Data)Checking the Setup Data 2. If the data ar

Page 41 - Setting the Modbus Master

2-34IM04L41B01-65EN2.8 Saving the Setup DataSaving the Setup DataSaves the setup data b specifying the save destination and file name. 2. The [Save

Page 42 - Setting the Web Server

2-35IM04L41B01-65EN1234IndexViewing and Creating Setup Data2.9 Printing the Setup DataSetting the Printer1. Select [File] - [Print Setup]. 2. Se

Page 43

2-36IM04L41B01-65EN2.10 Characters That Can Be UsedThe characters in the following table can be used when entering a group name, a view group name, a

Page 44 - Setting SNTP

3-1IM 04L41B01-65ENReceiving and Sending Setup Data1234Index3.1 Connecting to the DXPNotes about Sending and ReceivingNote• TheCommunicatorSoftwar

Page 45 - Checking the Setup Data

iiiIM 04L41B01-65EN4.3 WhenYokogawadecidesinitsownjudgementthatitisnecessary,YokogawamayfromtimetotimeprovidetheLicenseewithRele

Page 46 - 2.8 Saving the Setup Data

3-2IM 04L41B01-65EN3.2 Receiving Setup Data from the DXP 5. Click here.6. A progress indicator appears.7. The message “Receiving finished” appears

Page 47 - 2.9 Printing the Setup Data

3-3IM 04L41B01-65ENReceiving and Sending Setup Data1234Index3.3 Sending Setup Data to the DXP 4. Click here.5. A progress indicator appears.6. The m

Page 48

4-1IM 04L41B01-65ENTroubleshooting1234Index4.1 Messages and Corrective ActionsMessages may appear on the screen during operation. This section explai

Page 49 - 3.1 Connecting to the DXP

4-2IM 04L41B01-65ENWarning MessagesCode Message Corrective Action/ExplanationW7051 Save changes to NewFile? The setup information has been changed, bu

Page 50 - IM 04L41B01-65EN

IndexAA/Dintegrate... 2-20active storage change ...

Page 51 - IM 04L41B01-65EN

Indexsystem configuration... 2-2system relay ...

Page 52 - Error Messages

ivIM 04L41B01-65ENHow to Use This ManualStructure of the ManualThis manual consists of the following five chapters and index.Chapter Title Content1 B

Page 53 - Messages

vIM 04L41B01-65EN1234IndexContentsTermsandConditionsoftheSoftwareLicense...

Page 54

viIM 04L41B01-65ENChapter 3 Receiving and Sending Setup Data3.1 ConnectingtotheDXP .....

Page 55

1-1IM 04L41B01-65EN1234IndexBefore Using the DAQSTANDARD1.1 Overview of the DAQSTANDARDThe DAQSTANDARD consists of the following three utility progra

Commentaires sur ces manuels