6-48 IM 04L31A01-17E
Example Send report generation notification e-mail
messages including the source URL to recipient
1. The subject is “Report”, and the header is
“LP2”.
YUREPORT,ON,OFF,ON,Report,LP2
Description For the contents of the system notification,
see section 2.11.
Report generation notification can be used on
models with the computation function option /
M1.
For details on the settings of e-mail, see
sections 2.3 and 2.11.
YV Sets the e-mail recipient address
Syntax YV p1,p2<terminator>
p1: Select Recipient
1: Recipient 1
2: Recipient 2
p2: Recipient address (up to 150 characters)
Query YV[p1]?
Example Set recipient 1 to “[email protected]” and
Description To set multiple recipients, separate each
recipient with a space.
For details on the settings of e-mail, see
sections 2.3 and 2.11.
YW Sets the e-mail sender address
Syntax YW p1<terminator>
p1: Sender address (up to 64 characters)
Query YW?
Example Set the sender address to “CX2000”.
YWCX2000
Description For details on the settings of e-mail, see sections
2.3 and 2.11.
YX Sets the e-mail SMTP server
name
Syntax YX p1,p2<terminator>
p1: SMTP server name (up to 64 characters)
p2: Port number (0 to 65535).
Query YX?
Example Set the SMTP server to “mhs.good.com” and
port number to “25”.
YXmhs.good.com,25
Description For details on the settings of e-mail, see sections
2.3 and 2.11.
6.7 Basic Setting Commands (Measurement)
ML Sets the communication buffer
recovery processing
Syntax ML p1<terminator>
p1: DO/internal switches processing
Continue: hold the status
Clear: clear the status
Query ML?
Example During communication buffer recovery, clears
DO and the internal switches.
MLclear
MM Sets the modbus mouse/
temperature meter
communication automatic
recovery
Syntax MM p1,p2<terminator>
p1: Turns automatic recovery On/Off
p2: Intervals: 1min, 2min, 5min, 10min, 20min,
30min, or 60min.
Query MM?
Example Temperature meter communications
automatically restored after 5 minutes.
MMON,5min