Measurement Channels and Alarms
1
2
3
4
5
6
7
8
9
10
11
12
13
App
Index
3.3 Setting the Input Range
Range > Unit
Set the unit (up to six characters,
A
a
#
1
)
Range > Ref. CH
The reference channel for difference computation.
Range > Low-cut
Select On to use the low-cut function.
* The low-cut value for 1-5 V input is fixed at 0% of the input span.
Range > Low-cut value
With square root computation, set the low-cut value in the range of 0.0% to 5.0% of
the input span.
Input value
Low-cut value
Result of square root computation
Measured value