3-63
IM 04L41B01-62EN
Detailed Information for Attributes of Screens and Components
Attribute Set value/choice
(Underlined items are initial
set values)
Description, conditions
2nd span Lower
(On Version3
screens, no decimal
places allowed)
[0.0] to [90.0] The 2nd span lower limit is set between setting span lower limit (0.0 %)
and upper limit (100.0 %).
Setting is not possible when “2nd span” is [Off].
2nd span Upper
(On Version3
screens, no decimal
places allowed)
[10.0] to [100.0] The 2nd span lower limit is set between setting span lower limit (0.0 %)
and upper limit (100.0 %).
Setting is not possible when “2nd span” is [On].
Synchronize action
►Section 3.3
3.29 Attributes of Scale Components