MW100 CAN Bus Module
(MX118-CAN-M30/S1)
Users Manual
All Ri
g
hts Reserved. Co
py
ri
g
ht © b
y
Yoko
g
awa Electric Cor
p
oration IM MX118-S1E-1 Ed-02
Vue de la page 0
1 2 3 4 5 6 ... 16 17

Résumé du contenu

Page 1

1/17 MW100 CAN Bus Module (MX118-CAN-M30/S1) User’s Manual All Rights Reserved. Copyright © by Yokogawa Electric Corporation

Page 2 - Contents

10/17 4. Communication Commands 4.1.Setting the Input Range When setting p2=SKIP SR p1,p2<terminator> When p2=COM When p6=OFF SR p1,p2,p3,p4,

Page 3 - 1. Foreword

11/17 When Setting Difference between Channels Computation Syntax SR p1,p2,p3,p4,p5,p6,p7<terminator> p1 Channel range (001–060) p2 Input mod

Page 4 - 2. System Reconfiguration

12/17 5. PC Software Use PC software of the following release numbers or later. Software Software Name Release No. MW100 IP Setting Software

Page 5 - 3. Setup

13/17 6. CAN Bus Module (MX118-CAN-M30) Specifications 6.1.Model Name Model Name Description Max. Number of Channels Min. Sampling Interval Slot Wi

Page 6

14/17 For scaling computation When (Value width/Span width) > 1, Value width is changed to within the span width. For such settings, the resoluti

Page 7

15/17 Weight: Approximately 0.5 kg External dimensions: Approximately 57×131×150 mm Outer Dimensions Status LED: ACTIVE and STATUS (

Page 8

16/17 Dip Switch Settings -:Don’t care Note

Page 9

17/17 7. Switching between Setting and Measurement Mode When measuring (acquiring) CAN bus data on a CAN bus module, you can insert other I/O modules

Page 10 - 4. Communication Commands

2/17 Contents 1. Foreword ...

Page 11

3/17 1. Foreword This manual describes the functions, operating procedures, and handling precautions applicable to the CAN Bus Module (MX118-CAN-M30/

Page 12 - 5. PC Software

4/17 2. System Reconfiguration When connecting the MW100 for the first time, or when changing the position of an installed input/output module on the

Page 13 - 3 30 ch 4

5/17 3. Setup 3.1.Setting Up the Measurement Operation From the top screen, click System Settings > Measurement Setting under the Top item. Enter

Page 14

6/17 The relationship between the measurement interval and the maximum number of channels that can be set is the same as that in the MW100 standard sp

Page 15 - 6 7 8 9

7/17 3.2.Setting Up Measurement Channels You can set the input type, range, span, computations, difference input, and scale. Setting the Input Ran

Page 16 - 1 2 3 4 5 6 7

8/17 Note Linear scaling (SCALE) and difference input (DELTA) cannot be selected at the same time. If the input type setting does not match tha

Page 17 - CAN Bus

9/17 3.3.Setting Up Filters You can set filters for CAN measurement channels. The burnout and reference junction compensation settings are ignored