IM MX100-02E
6-CH, Medium-Speed 4-Wire RTD Resistance Input Module (MX110-V4R-M06)
• Minimum measurement interval: 100 ms
• Maximum number of inputs: 6 inputs
• Input types: DC voltage, 4-wire RTD, 4-wire resistance,
and DI (LEVEL, non-voltage contact)
4-CH, Medium-Speed Strain Input Module (MX112-B12-M04, MX112-B35-M04)
• Minimum measurement interval: 100 ms
• Maximum number of inputs: 4 inputs
• Input system: floating balanced input (isolation between channels)
4-CH, Medium-Speed Strain Input Module (MX112-NDI-M04)
• Minimum measurement interval: 100 ms
• Maximum number of inputs: 4 inputs
• Input system: floating balanced input
(non-isolation between channels)
10-CH, High-Speed Digital Input Module (MX115-D05-H10)
• Minimum measurement interval: 10 ms
• Maximum number of inputs: 10 inputs
• Input types: DI (non-voltage contact, open collector, 5-V logic)
10-CH, High-Speed Digital Input Module (MX115-D24-H10)
• Minimum measurement interval: 10 ms
• Maximum number of inputs: 10 inputs
• Input types: DI (24-V logic)
The 10-CH, Pulse Input Module (MX114-PSL-M10) cannot be used with the MX100.
For details see “Input/Output Modules” in section 1.1 of the MX100 Data Acquisition
Unit User’s Manual (IM MX100-01E).