User’sManualWX1GateWTIM WX1-03E8th Edition
1-4IM WX1-03ESystem Configuration GateWTTCP/IP connectionMonitor server protocolData transferRemote MonitorEthernetIt is recommended that you run Ga
2-1IM WX1-03E123IndexOperating ProcedureChapter 2 Operating Procedure2.1 Running and Exiting Gate-WTRunning the SoftwareProcedure1. From the Window
2-2IM WX1-03E2.2 Entering Environment SettingsThe following settings can be entered using the configurator. • WT assignments, communications settin
2-3IM WX1-03E123IndexOperating ProcedureWT SettingsProcedure1. Click the WT Setting tab or choose View > WT Setting from the menu bar. The WT S
2-4IM WX1-03E Automatic Model Determination3. Click Auto determination on the toolbar or choose Communication > Recorder Model Determination from
2-5IM WX1-03E123IndexOperating ProcedureExecuting the Test 5. Click the Test Execution button in the Tag Setting dialog box. The test result is di
2-6IM WX1-03ESaving Environment Settings Procedure1 Click the Save button on the tool bar or choose File > Save from the menu bar. Save bu
2-7IM WX1-03E123IndexOperating Procedure2.3 Connecting from DAQLOGGER or Remote MonitorWhile the executable function is running, DAQLOGGER or Remote
2-8IM WX1-03E2.4 Process Run/Stop and Service Run/StopRunning/Stopping from the Menu BarProcedureRunning as a Process or Service1. Click the Service
2-9IM WX1-03E123IndexOperating Procedure2.5 Viewing the Status of the Executable FunctionProcedureDisplaying the Connection Status1. Click the Execu
iIM WX1-03E8th Edition : October 2011 (YK)All Rights Reserved, Copyright © 2003 Yokogawa Electric Corporation This manual describes the functions and
2-10IM WX1-03E2.6 Viewing Version InformationProcedure1. Click the About button on the tool bar or choose Help > About from the menu bar.
3-1IM WX1-03E123IndexDetailed Description of FunctionsChapter 3 Detailed Description of Functions3.1 OverviewGateWT opens communications with WT ser
3-2IM WX1-03E3.2 Detailed Description of FunctionsSerial PortThe communications ports available to GateWT are the COM1–COM9 serial (RS-232) ports. T
3-3IM WX1-03E123IndexDetailed Description of FunctionsAutomatic Model DeterminationIf you select a WT and perform automatic model determination, the m
3-4IM WX1-03EPort SettingsGateWT uses the following ports. • Monitor server port The port used for communications from DAQLOGGER and Remote Monitor
3-5IM WX1-03E123IndexDetailed Description of FunctionsGroup and Channel AssignmentsIf connected from the remote monitor, the initial group and channel
3-6IM WX1-03EWT130 (Three-phase, three-wire), WT230(Three-phase, three-wire) [53]Group String Waveform Number Channel Assignment1 group Element1 W01—W
3-7IM WX1-03E123IndexDetailed Description of FunctionsWT1600(1Element model)Group String Waveform Number Channel Assignment1 group Element1 W01 URMSW0
3-8IM WX1-03EGroup String Waveform Number Channel Assignment3 group Other W01 ETAW02 SETAW03 F1W04 F2W05 F3W06 F4W07 DURMS1W08 DUMN1W09 DUDC1W10 DUAC1
3-9IM WX1-03E123IndexDetailed Description of FunctionsWT1600(4Elements model)Group String Waveform Number Channel Assignment1 group Element1 W01—W27 U
iiIM WX1-03ESoftware License AgreementIMPORTANT - PLEASE READ CAREFULLY BEFORE INSTALLING OR USING:THANK YOU VERY MUCH FOR SELECTING SOFTWARE OF YOKOG
3-10IM WX1-03EWT1800(1Element model)Group String Waveform Number Channel Assignment1 group Element1 W01 URMSW02 UMNW03 UDCW04 IRMSW05 IMNW06 IDCW07 PW
3-11IM WX1-03E123IndexDetailed Description of FunctionsNote• Since the maximum number of parameters that can be acquired via communications on the WT
3-12IM WX1-03EWT1800(3Elements model)Group String Waveform Number Channel Assignment1 group Element1 W01—W20 URMS—AHM2 group Element2 W01—W20 URMS—AHM
3-13IM WX1-03E123IndexDetailed Description of FunctionsWT1800(6Elements model)Group String Waveform Number Channel Assignment1 group Element1 W01—W20
3-14IM WX1-03EWT500(1Element model)Group String Waveform Number Channel Assignment1 group Element1 W01 URMSW02 UMNW03 UDCW04 URMNW05 UACW06 IRMSW07 IM
3-15IM WX1-03E123IndexDetailed Description of FunctionsGroup String Waveform Number Channel Assignment3 group Sigma W01 URMSW02 UMNW03 UDCW04 URMNW05
3-16IM WX1-03EWT500(2Elements model)Group String Waveform Number Channel Assignment1 group Element1 W01—W32 URMS—WQ2 group Element2 W01—W32 URMS—WQ3 g
3-17IM WX1-03E123IndexDetailed Description of FunctionsTag SettingsInitial settings of the tags are assigned according to the model information obtain
3-18IM WX1-03EWT1600Tags set to group ElementX are the same as those for Element1. Tags set to group SigmaX are the same as those for SigmaA. NoteSi
3-19IM WX1-03E123IndexDetailed Description of FunctionsWT1800Tags set to group ElementX are the same as those for Element1. Tags set to group ElemHrmX
iiiIM WX1-03E5. Infringement5.1 If you are warned or receive a claim by a third party that the Software Product in its original form infringes any thi
3-20IM WX1-03EWT1800 (5Elements) Groupe 1 (Element1) Element1 (URMS—AHM)Groupe 2 (Element2) Element2 (URMS—AHM)Groupe 3 (Element3) Element3 (URMS—AHM)
3-21IM WX1-03E123IndexDetailed Description of FunctionsWT500Tags set to group ElementX are the same as those for Element1.Note• With the WT500, becau
3-22IM WX1-03EA list of function names used in this manual and function names used on the WT1600 (Numerical display header name)Function names used in
3-23IM WX1-03E123IndexDetailed Description of FunctionsA list of function names used in this manual and function names used on the WT1800 (Numerical d
3-24IM WX1-03EA list of function names used in this manual and function names used on the WT500 (Numerical display header name)Function names used in
3-25IM WX1-03E123IndexDetailed Description of FunctionsChannel Names, Tag IDs, and Tag NamesGateWT’s default channel names and tag IDs are the same: E
3-26IM WX1-03EGateWT is started and the data of a possible data collection from WT1600GateWT doesn’t correspond to “Harmonic component mode.” Therefor
3-27IM WX1-03E123IndexDetailed Description of FunctionsGateWT is started and the data of a possible data collection from WT1800Element1Element2Element
3-28IM WX1-03EUser-defined function 15 F15User-defined function 16 F16User-defined function 17 F17User-defined function 18 F18User-defined function 19
3-29IM WX1-03E123IndexDetailed Description of FunctionsGateWT is started and the data of a possible data collection from WT500Element1 Element2 Elemen
ivIM WX1-03EOverview of This ManualStructure of This ManualThis user’s manual consists of the following chapters. Chapter Title Description1 Overview
3-30IM WX1-03EElement1 Element2 Element3 ΣEquation for efficiency 1 ETA1Equation for efficiency 2 ETA2User-defined function 1 F1User-defined function
3-31IM WX1-03E123IndexDetailed Description of Functions3.3 Error Messages and Corrective ActionsErrorNo. Message Corrective ActionsE211 Cannot write
Index-1IM WX1-03E123IndexIndexIndexAautomatic model determination ... 2-4, 3-3Cchannel colors ...
vIM WX1-03E123IndexContentsSoftware License Agreement ...
1-1IM WX1-03E123IndexOverviewChapter 1 Overview1.1 Overview of GateWT FunctionsGateWT is a software program that acquires data from WT series instru
1-2IM WX1-03E1.2 System OverviewSystemThis software can connect with and download data from a WT series instrument having the following characteristi
1-3IM WX1-03E123IndexOverview• GP-IB port: Required for GP-IB communications between the software and a WT series instrument Pl